Research

Energy Saving Estimation of ASHRAE Guideline 36 Supervisory Setpoint Reset Controls in a Commercial Large Office Building

DOE

Source: doe_osti

Questions this answers

Sources

Source record

The underlying research record — supporting evidence for the object above.

Key Details

Posted Date
Source
doe_osti

Description

Designing, commissioning, and retrofitting HVAC control systems for energy efficiency is crucial, but the use of ad-hoc control sequences by designers and contractors, based on scattered information, results in diverse and sub-optimal sequences. ASHRAE Guideline 36 (G36) addresses the challenge by providing standardized, rule-based HVAC control sequences that prioritize energy efficiency. However, there is limited evaluation of their energy performance at the building level, with only a few studies primarily focused on HVAC airside systems in small-to-medium-sized commercial buildings. In this study, the energy performance of ASHRAE Guideline 36 control sequences was assessed using a large office building emulator in Chicago. The emulator features a central plant system with multiple chillers and boilers as well as multiple variable air volume (VAV) systems with terminal reheat. To achieve a high-fidelity representation, we developed a Spawn-of-EnergyPlus-based model for the large office building, maintaining the DOE prototype large office building setup but substituting the HVAC system with its Modelica counterpart. This substitution ensures that the building thermal load, HVAC system's dynamics, and detailed control sequences are all accurately represented. The study involved evaluating and implementing control strategies outlined in ASHRAE Guideline 36-2021 to replace conventional controls. These strategies include the demand-based supply air temperature and duct static pressure setpoint reset and the request logic for demand-based reset of chilled/hot water supply temperature setpoints and pipe static pressure setpoints. Energy performance was evaluated under various load conditions, including cooling, heating, and transitional seasons, both for individual control strategies and in combination. The results indicate that the collective control strategies retrofit yield greater energy savings than the sum of individual strategies, highlighting the synergistic bene. Authors: Lu, Xing [BATTELLE (PACIFIC NW LAB)]; Chen, Yan [BATTELLE (PACIFIC NW LAB)] (ORCID:0000000229889136). DOE Contract: AC05-76RL01830. Subjects: ASHRAE Guideline 36, Commercial buildings, Control, Energy efficiency, Modelica, Large Office

Frequently Asked Questions

What is this record?+
It is a publication associated with DOE — published findings, a technical standard, or a notice. It reports results or specifications. There is nothing here to apply for.

Where this record sits

What else do you want to know?

100M+ government records — search across all categories