A Comprehensive Study of the Impact of Inverter-Based Resource (IBR) Modeling and Control on Protection Relay Elements

DOE

Source: doe_osti

Questions this answers

Sources

Source record

The underlying research record — supporting evidence for the object above.

Key Details

Posted Date
Source
doe_osti

Description

Inverter-based resources (IBRs) exhibit fault responses that differ significantly from those of synchronous generators, which can challenge the reliable operation of many commonly used power system protection elements. The fault response of IBRs is primarily influenced by their control algorithms and configurations, but the impact of these controls on protection relays is not yet fully understood. This presentation provides a comprehensive study of how IBR modeling and controls affect transmission line protection. Key modeling and control aspects include the DC source, inverter model, power level control, current control, and current limiting. The study reveals that certain aspects - such as the type of DC source (battery, PV, or hybrid), inverter model (average vs. switching), and power level control methods (PQ dispatch vs. Vdc-Vac control for grid-following IBRs, and droop vs. VSM for grid-forming IBRs) - do not significantly affect relay response. However, faster control loops, such as current control and current limiting, do influence the relay behavior. Additionally, the study explores the effects of other factors, including momentary cessation, operating points, fast/slow current responses, and grid strength on relay performance. Finally, the study offers recommendations for both IBR and protection engineers to improve IBR fault response and enhance the reliability of protection systems.. Authors: Wang, Jing [National Renewable Energy Lab., Golden, CO (United States)]; Pinheiro, Paulo Henrique [University of Idaho]; Chakraborty, Soham [National Renewable Energy Lab., Golden, CO (United States)]; Johnson, Brian [University of Idaho]; Goncalves Bainy, Romulo [University of Idaho]. DOE Contract: AC36-08GO28308. Subjects: 14 SOLAR ENERGY; 24 POWER TRANSMISSION AND DISTRIBUTION; IEEE 2800 compliant negative sequence current; differential element; direction element; distrance element; transmission line protection

Frequently Asked Questions

What is this record?+
It is a publication associated with DOE — published findings, a technical standard, or a notice. It reports results or specifications. There is nothing here to apply for.

Where this record sits

What else do you want to know?

100M+ government records — search across all categories